• ARA-120-AME  Duplex/Triplex Alternator With Selector Switch Allowing Removal of One of Three Motors. 120vac Surface Mount
Item Number:   ARA120AME
Brand:   Diversified Electronics
Item Category:   Relays
Subcategory:   Alternating
Series:                                                                                          
ARA
  Control Voltage:   120 Volts AC
  Operation:   2-Channel (Duplexor);3-Channel (Triplexor)
  Contact Rating @ 120VAC:   5 Amps
  Termination:   Screw Terminals
  Mounting:   Surface
  Status Indicator:   Yes


Diversified Electronics

Alternating Relays, ARA Series
ARA120AME - Expandable Alternating Relay
ARA Series Information
  • Two‑, Three‑, and Four‑Load Units Available
  • Automatic Alternating or External Clocking
  • LEDs Show Position Of Output
  • Plug-in or Surface Mount
  • In the Event of a Power Failure, Relays Will Return to Their Quiescent State and Continue Sequencing Loads One‑at‑a‑Time

The Alternating Relay is used in multiple‑load installations to assure equal run time on all loads. They also allow for the addition of more capacity in the event of excess load requirements. The Alternating Relay provides equal run time on two or more loads by alternating the sequence in which the loads are allowed to start up. In each case, the alternating action is initiated each time the control switch across designated terminals opens. The control switch may be a float, a thermostat, a pressure switch, or a timer contact.

ARA series duplexors and quadraplexors from the ATC Diversified Electronics Division of Marsh Bellofram are designed for use in multiple load installations that are required to alternate in sequence while assuring equal run time on all loads. They also allow for additional loads to run in the event of excess load requirements, with the option of automatic or external clocking alterations. When the factory installed jumper is in place, the alternating action is initiated by a control switch, which is common to one side of the control voltage. When the jumper is removed, alternating action is initiated by an isolated normally open switch.
ARA-XXX-AFE Alternating Action

Triplexor: For automatic alterations, a factory-installed jumper is in place between terminals 3 and 4. The alternating action is accomplished when the control switch between terminals 2 and 4 opens. For external clocking alterations, the factory-installed jumper between terminals 3 and 4 is removed and replaced by an isolated normally open switch between terminals 2 and 3. The alternating action will occur each time this isolated switch is closed and then re-opened.

ARA-XXX-AGE
Quadraplexer: For automatic alterations, a factory installed jumper is in place between terminals 11 and 12. The alternating action is accomplished when the control switch between terminals 2 and 3 opens.
For external clocking alterations, remove the factory-installed jumper between terminals 11 and 12 and place an isolated normally open switch between terminals 2 and 12. The alternating action will occur each time this isolated switch is closed and then re-opened. In the event of a power failure the Alternating Relays will return to their quiescent state and continue sequencing loads on one-at-a-time.

Applications
· Municipal water plants
· Wastewater treatment facilities
· Large aquarium pumps
· Water well installations
· Level and pumping control systems
· Industrial pump level monitoring

 

Alternators
Operation Duplex,Triplex
Voltage 120vac
Mounting Surface Mount

ARA-120-AME Duplex/Triplex Alternator With Selector Switch Allowing Removal of One of Three Motors. 120vac Surface Mount

  • $394.41